Debugging Method Of Centrifugal Fan

Centrifugal fan is a complex equipment, mainly composed of air inlet, air valve, impeller, motor and air outlet. Under different conditions, the effect of centrifugal fan is different. Therefore, when the operating conditions of different parts are different, the effect of centrifugal fans will be affected. There are many ways to debug the centrifugal fan to the best state.


1. The centrifugal fan is allowed to be started at full voltage or electrically driven at reduced voltage, but it should be noted that the current during full voltage starting is about 5-7 times of the rated current, and the reduced voltage starting torque is proportional to the square of the voltage. When the grid capacity is insufficient, the reduced voltage starting should be used.


2. During the commissioning of centrifugal fan, carefully read the product manual and check whether the wiring method is consistent with the wiring diagram; Carefully check whether the working voltage supplied to the fan power supply meets the requirements, whether the power supply is out of phase or in phase, and whether the capacity of the electrical components provided meets the requirements.


3. During commissioning, the number of people shall not be less than two. One person shall control the power supply and the other person shall observe the operation of the fan. In case of any abnormality, stop the machine for inspection immediately; First, check whether the rotation direction is correct; After the centrifugal fan starts to run, immediately check whether the running current of each phase is balanced and whether the current exceeds the rated current; In case of any abnormality, stop the machine for inspection. After five minutes of operation, stop the machine to check whether the fan is abnormal, and start the machine again after confirming that there is no abnormal phenomenon.


4. During the commissioning of the two speed centrifugal fan, the low-speed fan shall be started first to check whether the rotation direction is correct; When starting at high speed, the fan must be stopped before starting to prevent switch tripping and motor damage due to high-speed reverse rotation.


5. When the centrifugal fan reaches the normal speed, measure whether the fan input current is normal, and the operating current of the centrifugal fan cannot exceed its rated current. If the operating current exceeds its rated current, check whether the voltage supplied is normal.


6. The motor power required by centrifugal fan refers to the higher power required for centrifugal fan and fan box when the air inlet is fully open under certain working conditions. If the air inlet is fully opened for operation, the motor may be damaged. During fan commissioning, it is better to close the valve on the inlet or outlet pipe of the fan, open the valve gradually after operation until the required working condition is reached, and pay attention to whether the operating current of the fan exceeds the rated current.


The centrifugal fan can be debugged in strict accordance with the above debugging methods, and the efficiency of the centrifugal fan can reach more.