(1) Only one of the four rectifier diodes has a problem
(2) There is carbon powder between the motor rotor and the commutator or the carbon brush itself is defective, etc. In line with the repair principle of easy first and then difficult, first measure the adjustable resistance, and the resistance value changes regularly with adjustment, which proves that the potentiometer is Ok, no problem was found by measuring the thyristor again. Since the diode is a high-current gold-sealed tube, one end is fastened to the circuit board with a screw, and the other end is welded to the circuit board with a wire. When it is removed from the circuit board , found that the positive and negative poles are loose, and then shake while measuring, confirming that the diode is good and bad.
(3) There are also many problems with thyristor, usually breakdown short circuit, open circuit, inability to trigger or poor internal contact.
(4) Adjustable resistance. The cabinet centrifugal fan is installed on the control panel due to the adjustable resistance. The frequency of use is very high, and it is very common to have poor contact after a long time.